PP and PVDF housings

PP and PVDF cartridge fi lter housings made of plastic

PP and PVDF housings

Multi-housings made of polypropylene or PVDF for the installation of 3, 5, 7 or 12 fi lter cartridges in the lengths 10“, 20“, 30“ or 40“. The cover can be removed without tools, but with the aid of plastic star-grips. Apart from the connections for in- and outlet the housing has a ½“ vent plug as well as two ½“ drain plugs for dirt- and clean side. The connections for both in- and outlet are equipped with either a fl ange or GF connection piece which can be screwed on. Custom made equipment such as manometers or additional instrumentation as well as special inlet/outlet posi-tions and connection types are available on request. For higher pressures or higher temperatures covers and container fl ange with a stainless steel reinforcement are implemented. All housings undergo a compression test in the factory, before beingreleased for dispatch. Filter cartridge versions with center posts and plug-in adapters can be exchanged easily by screwing the nut on without having to remove the adapter from the intermediate plate. All general-use fi lter elements with double open ends can be used. If center posts are removed, fi lter cartridges with Code 0 or Code 5 adapters can be used. An additional centering and pressure device can be provided for multi-housings. This attaches the cartridges and prevents them from being pushed off the intermediate plate by pressure impacts which go against the fi lter direction.

Technical Data

Material

Housing: polypropylene or PVDF
O-Ring: Viton / Cover reinforcement: 1.4301

In-/Outlet:

See table

Vent

½“

Drainage

2 x ½“

Filter elements

Code 0: 10“, 20“, 30“ or 40“
Code 5: 10“, 20“, 30“ or 40“
DOE: 9 ¾“, 10“, 19 1/2“, 20“29 ¼“, 30“, 39“ or 40“

Pressure

PP Housings:
5 bar @ 30 ̊C without cover reinforcement
6 bar @ 30 ̊C with cover reinforcement

PVDF Housings:
7 bar @ 30 ̊C without cover reinforcement
8 bar @ 30 ̊C with cover reinforcement

Temperature

PP Housings:
50 ̊C @ 3bar without cover reinforcement
60 ̊C @ 3bar with cover reinforcement

PVDF Housings:
80 ̊C @ 3bar without cover reinforcement
90 ̊C @ 3bar with cover reinforcement

Flow rate

The maximum flow rate correlates to the nominal diameter of the housing connection and the characteristic curve of the flow rate of the chosen filter element.

Features and Benefits

  • Cartridge filter housing made of plastic
  • Made entirely of polypropylene or PVDF
  • For 3 to 12 filter elements of 9 ¾“ to 40“ in length
  • Applicable for filter elements of type DOE, code 0 or code 5
  • With cover reinforcement for increased pressures and temperatures
  • With flange connection or GF connection part for inlet/outlet

Datasheet

You have a question?