WP housings are used for the insertion of CLC Lenticular filter elements and are made of stainless steel AISI316L (1.4404). The housing fastening of the standard versions come with a v-clamp; the fastening can also be delivered with swinging bolt or bracket screw. The construction of the WP housings is optimal in regard to cleaning and sterilisation. In this respect the housing bolt can be lifted off the top and the separation of the dirt- and clean side takes place directly on the retaining plate of the filter element without an intermediate plate. WP housings are sanitary versions and electro-polished on the inside as well as on the outside.
WP housings can take up between one to four CLC Lenticular filter cartridges in the diameters of 12“ and 16“. The 12“-elements have a filter area of 1.8 m2 and the 16“-elements have a filter area of 3.6 m2 Therefore it is possible to accom-modate a filter surface of up to 14.4 m2 in one WP housing.
Material | Dome: Stainless steel AISI316L (1.4404) |
In-/Outlet |
See table
|
Vent |
DN40
|
Drainage |
Pharma-valve
|
Filter elements | 12WP: CLC12 |
Installations |
Stainless steel AISI316L (1.4404)
|
Pressure |
Max. 6 bar
|
Temperature |
Max. 95ºC (sterilisation 150 ºC)
|
Flow rate | The maximum flow rate correlates to the nominal diameter of the housingconnection and the characteristic curve of the flow rate of the chosen filter element.
|